Well suited for use with every cataract procedure, Amvisc is a general-purpose viscoelastic that is both effective and efficient. WithAmvisc, there is a variety of bottom-line advantages.

  • The high viscosity of Amvisc enables it to achieve excellent chamber maintenance during lens insertion and removal
  • High cohesion makes complete viscoelastic removal quick and easy
Amvisc Order Information:

Size:

 Part Number:

0.8mL

59081L

Amvisc Viscoelastic - Brief Statement

Indications
Amvisc and Amvisc Plus are indicated for use as surgical aids in ophthalmic anterior and posterior segment surgery including cataract extraction, intraocular lens (IOL) implantation, corneal transplantation and glaucoma filtering surgery, and surgical procedures to reattach the retina. Due to its lubricating and viscoelastic properties, transparency and ability to protect corneal endothelial cells, Amvisc and Amvisc Plus help maintain anterior chamber depth and visibility, minimizes interaction between tissues, and acts as a tamponade and vitreous substitutes during retina reattachment surgery. Amvisc and Amvisc Plus also preserve tissue integrity and good visibility when used to fill the anterior and posterior segments of the eye following open sky procedures.

Contraindications
There are no contraindications to the use of Amvisc or Amvisc Plus when used as recommended as an intraocular implant.

Precautions
Amvisc and Amvisc Plus viscoelastics are prepared from a biological source and the physician should be aware of the possible effects of using biological materials. Precautions normally considered during anterior segment and retinal attachment procedures are recommended.

An excess quantity of Amvisc or Amvisc Plus should not be used; Amvisc and Amvisc Plus should be removed from the anterior chamber at the end of surgery; and, if the postoperative intraocular pressure increases above expected values, correcting therapy should be administered.

There may be increased postoperative intraocular pressure due to pre-existing glaucoma or by the surgery itself. 

There have been isolated reports of particulates or haziness after the injection of Amvisc or Amvisc Plus. Particulates should be removed by irrigation and/or aspiration.

Adverse Events
Transient postoperative inflammatory reactions; transient postoperative increase in intraocular pressure following use in anterior segment surgery; and, on rare occasions, postoperative reactions including inflammation, corneal edema and corneal decompensation.