Bausch + Lomb ULTRA for Presbyopia contact lenses

MoistureSeal technology


Exceptional all-day comfort1

3-Zone Progressive Design


Outstanding vision near, far, and in-between

Easy, predictable fitting1

A lens designed to meet the challenges today’s presbyopes face

When using a digital device, patients may blink 66% less on average,1 which could contribute to dehydration


Dryness

  • 1 of 3 multifocal contact lens wearers cite dryness as an issue2
  • 1 of 3 Gen Xers and 1 of 4 Baby Boomers spend at least 9 hours per day on digital devices3*



*Gen Xers are people born 1965-1980. Baby Boomers are people born 1946-1964.5


3-Zone Progressive Design

Provides clear near and intermediate vision without compromising distance1


Vision

  • 3 of 4 multifocal contact lens wearers state good near and intermediate vision at
    work is a priority4
  • And more than 70% of those wearers report frequent difficulty seeing clearly at
    these distances4






MoistureSeal Technology

Helps maintain 95% of lens moisture for a full 16 hours1

Proprietary, two-phase manufacturing process retains moisture and delivers a highly wettable surface1

Phase 1

  • Combines long- and short-chain monomers to formulte a unique silicone backbone
  • Produces a material that delivers a Dk/t of 163 and modulus of 70

Phase 2

  • PVP grows around and throughout the silicone backbone

Moisture retention in lens core

High volume of PVP at the core provides
excellent moisture retention

High wettability at lens surface

Tightly compact PVP at the
surface delivers high wettability



9 out of 10 patients agree that Bausch + Lomb ULTRA contact lenses are as comfortable at the end of the day as they are at the beginning5*

*Study using Bausch + Lomb ULTRA spherical lenses.



Bausch + Lomb ULTRA for Presbyopia: Excellent Material Properties1


*Material release date is initial release of material in US market.
†Measured water content.



3-Zone Progressive Design

3-Zone Progressive Design delivers outstanding near, intermediate, and distance vision1

Patients rate vision clarity in real-world experiences



3-Zone Progressive Design: designed for a successful first fit*

Achieve an easy fit across all powers and from patient to patient with1:

  • Consistent Add power at every power
  • Simplified Fitting Guide
  • Only 2 Add powers for ease of fitting (low Add up to +1.50 and high Add up to +2.50)

First Fit Best Practices

  • Use spectacle refraction to select initial lens
  • Do not use the current precription for other multifocal lenses
Add Selection: for initial lens fitting

 SPECTACLE Add  BOTH EYES 
 +.075D to +1.50D  Low Add
 +1.75D to +2.50D  High Add

For refinements, download the fitting guide



Demonstrated fitting success by your peers6*


of patients were
sucessfully
fit in one visit

of patients were
successfully
fit in two visits

of ECPs agreed 
that the fitting guide
made it easy to fit

* When the ECP followed the fitting guide for the 3-Zone Progressive Design of PureVision2 for Presbyopia lens


Parameters

Material: samfilcon A
Technology: MoistureSeal
Water content: 46%
Oxygen Transmissibility: 163 Dk/t @ center for -3.00D
Lens Design Technology: 3-Zone Progressive Design, center-near aspheric optics
Base curve: 8.5 mm
Diameter: 14.2 mm
Center Thickness: 0.07 mm for -3.00D
Spherical Power:

+4.50D to -10.00D in 0.25D steps (including plano)

Add Power:

Low: +0.75D to +1.50D spectacle Add
High: +1.75D to +2.50D spectacle Add

Visibility tint: Light blue
Modality: Monthly; Daily wear indication

Bausch + Lomb ULTRA for Presbyopia contact lenses: Additional information


There's a Bausch + Lomb ULTRA contact lens for a wide range of patients in your practice.


References:
1. Data on file. Bausch & Lomb Incorporated. Rochester, NY; 2. The Multi-sponsors Survey's 2015 Gallup study of the US multi-focal contact lens market. October 2015. 3. The Vision Council. Hindsight is 20/20/20: protecting your eyes from digital devices. 2015 Digital Eye Strain Report. thevisioncouncil.org. 4. Kadence International. PureVision2 Multi-Focal contact lenses For Presbyopia Quantitative Testing. July 2012. 5. Results of an online survey with patients that wore their lenses for 7+ days and on average, spend 3 or more hours a day on a digital device (n=465). Survey questions were top 3-box scores (% Strongly Agree, Agree, Slightly Agree) on a 6-point agreement scale, with a margin of error +/- 2.4%. 6. Thirty-nine ECPs (from 10 countries) refitted 441 existing soft contact lens wearing presbyopes into PureVision2 Presbyopia lenses. Patients returned for follow-up visits after 1-2 weeks. ECP assessment of lens performance including ease of fit, and patient satisfaction with lenses in real-world conditions, were measured using a 6-point agreement survey. 7. Results of an online survey with habitual presbyopic contact lens wearers who wore their lenses for approximately 5 days (n=181). Survey questions were top 3-box scores (% Strongly Agree, Agree, Slightly Agree) on a 6-point agreement scale.

UFP.0076.USA.17